Sizing Guide Search

IQD20/IW126RA Part Turn Isolating Combination

Output Performance
Combination Rated Torque Stroke Time Fail Safe
  Nm lbsft Secs (50 Hz)  
IQD20/IW126RA 108120 79500 988.3 No
Available Output Flanges Available Enclosures Weight
(ISO5211 "F" & MSS SP-101 "FA") Hazardous Watertight Kg Lbs
F40/FA40, F48/FA48, F60/FA60 Yes Yes 1259.75 2777
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
IW_12_13_BSK Bore and Square Key 241 9.50 241 9.50 0 0.00
Warnings:
Stroke time over 600 seconds
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
IQD20 136 100 36.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
No No DC 110V
Yes Yes 56.75 125
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard Direct 1.0 593 632 142
Option 1 Geared 13.3 7886.9 231 52
Sales/Technical Information: IQD - Direct Current (DC)
Gearbox Performance
Size Rated Torque Ratio MA Weight
  Nm Lbsft (:1)   Kg Lbs
IW126RA 180000 132761 2372 795.0 1203.00 2652
Sales/Technical Information: IW Motorised

Enter your specific requirements and click ‘Add to enquiry’

Fields marked with an * are required.

« Go Back