Sizing Guide Search

IQD25/IW116R Part Turn Isolating Combination

Output Performance
Combination Rated Torque Stroke Time Fail Safe
  Nm lbsft Secs (50 Hz)  
IQD25/IW116R 90280 66600 765.8 No
Available Output Flanges Available Enclosures Weight
(ISO5211 "F" & MSS SP-101 "FA") Hazardous Watertight Kg Lbs
F40/FA40, F48/FA48, F60/FA60 Yes Yes 596.75 1315
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
IW_10_11_BSK Bore and Square Key 187 7.38 187 7.38 0 0.00
Warnings:
Stroke time over 600 seconds
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
IQD25 305 225 18.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
No No DC 110V
Yes Yes 56.75 125
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard SSHW 13.3 3055.7 519 117
Option 1 Direct 1.0 229.8 1418 319
Sales/Technical Information: IQD - Direct Current (DC)
Gearbox Performance
Size Rated Torque Ratio MA Weight
  Nm Lbsft (:1)   Kg Lbs
IW116R 141000 103996 919 296.0 540.00 1190
Sales/Technical Information: IW Motorised

Enter your specific requirements and click ‘Add to enquiry’

Fields marked with an * are required.