Sizing Guide Search

IQS20/IW52R Part Turn Isolating Combination

Output Performance
Combination Rated Torque Stroke Time Fail Safe
  Nm lbsft Secs (50 Hz)  
IQS20/IW52R 6160 4543 38.0 No
Available Output Flanges Available Enclosures Weight
(ISO5211 "F" & MSS SP-101 "FA") Hazardous Watertight Kg Lbs
F14/FA14, F16/FA16, F25/FA25 Yes Yes 122.03 269
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
IW_5_BSK Bore and Square Key 70 2.75 70 2.75 0 0.00
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
IQS20 80 59 96.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
Yes No No Yes Yes 54.03 119
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard Direct 1.0 60.8 372 84
Option 1 Geared 13.3 808 136 31
Sales/Technical Information: IQS - 1-Phase
Gearbox Performance
Size Rated Torque Ratio MA Weight
  Nm Lbsft (:1)   Kg Lbs
IW52R 6670 4920 243 77.0 68.00 150
Sales/Technical Information: IW Motorised

Enter your specific requirements and click ‘Add to enquiry’

Fields marked with an * are required.

« Go Back