CK250/IW126R Part Turn Isolating Combination

Output Performance
Combination Rated Torque Stroke Time Fail Safe
  Nm lbsft Secs (50 Hz)  
CK250/IW126R 49500 36432 175.0 No
Available Output Flanges Available Enclosures Weight
(ISO5211 "F" & MSS SP-101 "FA") Hazardous Watertight Kg Lbs
F40/FA40, F48/FA48, F60/FA60 No Yes 1247.00 2749
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
IW MTW 12 13 Bore and Rectangular Key 305 10.25 305 10.25 0 0.00
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
CK250 250 184 48.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
No Yes No No Yes 79.00 174
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard SSHW 10.0 1400 380 85
Gearbox Performance
Size Rated Torque Ratio MA Weight
  Nm Lbsft (:1)   Kg Lbs
IW126R 180000 132761 560 198.0 1168.00 2575