Sizing Guide Search

CK30/IW106R Part Turn Isolating Combination

Output Performance
Combination Rated Torque Stroke Time Fail Safe
  Nm lbsft Secs (50 Hz)  
CK30/IW106R 29490 21626 1942.5 No
Available Output Flanges Available Enclosures Weight
(ISO5211 "F" & MSS SP-101 "FA") Hazardous Watertight Kg Lbs
F35/FA35, F40/FA40, F48/FA48, F60/FA60 No Yes 437.96 965
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
IW_MOW_MTW_10_NRS Bore and Rectangular Key 203 7.63 203 7.63 0 0.00
Warnings:
Stroke time over 600 seconds
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
CK30 30 22 24.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
Yes No No No Yes 29.96 66
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard SSHW 10.0 7770 138 31
Gearbox Performance
Size Rated Torque Ratio MA Weight
  Nm Lbsft (:1)   Kg Lbs
IW106R 100000 73756 3108 983.0 408.00 899
Sales/Technical Information: IW Motorised

Enter your specific requirements and click ‘Add to enquiry’

Fields marked with an * are required.

« Go Back