Sizing Guide Search

90AA Multi Turn Isolating Combination

Output Performance
Combination Rated Torque Rated Thrust Resultant Thrust Stroke Time
  Nm lbsft kN lbsf kN lbsf Secs (50 Hz)
90AA 868 640 333.62 75000 0.00 0 0.0
Available Output Flanges Available Enclosures Weight Fail Safe
(ISO5210 "F" & MSS SP-102 "FA") Hazardous Watertight Kg Lbs  
F30/FA30 No Yes 217.47 479 No
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
A Thrust Base - Key 0 0.00 57 2.25 0 0.00
Warnings:
Due to the effects of inertia and drive nut/stem wear, speed not recommended for direct mounted gate valve applications.
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
90AA 868 640 144.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
No Yes No No Yes 217.47 479
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard SSHW 15.0 - 573 129
Option 1 Geared 45.0 - 156 35
Sales/Technical Information: AWT

Enter your specific requirements and click ‘Add to enquiry’

Fields marked with an * are required.

« Go Back