Sizing Guide Search

IQ25A Multi Turn Isolating Combination

Output Performance
Combination Rated Torque Rated Thrust Resultant Thrust Stroke Time
  Nm lbsft kN lbsf kN lbsf Secs (50 Hz)
IQ25A 149 110 100.00 22480 0.00 0 0.0
Available Output Flanges Available Enclosures Weight Fail Safe
(ISO5210 "F" & MSS SP-102 "FA") Hazardous Watertight Kg Lbs  
F14/FA14 Yes Yes 51.76 114 No
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
A Thrust Base - Threaded 0 0.00 38 1.50 0 0.00
Warnings:
Due to the effects of inertia and drive nut/stem wear, speed not recommended for direct mounted gate valve applications.
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
IQ25A 149 110 144.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
No Yes No Yes Yes 51.76 114
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard Direct 1.0 - 459 103
Option 1 Geared 13.5 - 197 44
Sales/Technical Information: IQ Pro Standard

Enter your specific requirements and click ‘Add to enquiry’

Fields marked with an * are required.