Output Performance |
Combination |
Rated Torque |
Stroke Time |
Fail Safe |
|
Nm |
lbsft |
Secs (50 Hz) |
|
CK120/IW6R |
8640 |
6408 |
95.0 |
No |
Available Output Flanges |
Available Enclosures |
Weight |
(ISO5211 "F" & MSS SP-101 "FA") |
Hazardous |
Watertight |
Kg
|
Lbs
|
F16/FA16, F25/FA25, F30/FA30 |
No |
Yes |
118.50 |
261 |
Couplings |
Coupling name |
Coupling Type |
Standard Dimension |
Max Dimension |
Min Dimension |
|
|
mm |
in |
mm |
in |
mm |
in |
IW_6_BSK |
Bore and Square Key |
92 |
3.75 |
92 |
3.75 |
0 |
0.00 |
Actuator Performance |
Size |
Rated Torque |
Output RPM |
Rating |
|
|
Nm |
lbsft |
RPM (50Hz)
|
Starts / Hour
|
|
CK120 |
120 |
89 |
36.00 |
60 |
|
Available for power supply
|
Available Enclosures
|
Weight
|
1-Phase AC
|
3-Phase AC
|
DC
|
Hazardous |
Watertight |
Kg |
Lbs |
No |
Yes |
No |
No |
Yes |
39.50 |
87 |
Handwheel
|
Type
|
Ratio
|
Turns
|
Rimpull
|
|
|
(:1)
|
(per stroke)
|
N
|
Lbsf
|
Standard |
SSHW |
10.0 |
570 |
325 |
73 |
Gearbox Performance |
Size |
Rated Torque |
Ratio |
MA |
Weight |
|
Nm
|
Lbsft
|
(:1)
|
|
Kg
|
Lbs
|
IW6R |
9924 |
7320 |
228 |
72.0 |
79.00 |
174 |
Enter your specific requirements and click ‘Add to enquiry’
Fields marked with an are required.