Sizing Guide Search

IQS35/MTW11R Multi Turn Isolating Combination

Output Performance
Combination Rated Torque Rated Thrust Resultant Thrust Stroke Time
  Nm lbsft kN lbsf kN lbsf Secs (50 Hz)
IQS35/MTW11R 54080 39884 0.00 0 0.00 0 0.0
Available Output Flanges Available Enclosures Weight Fail Safe
(ISO5210 "F" & MSS SP-102 "FA") Hazardous Watertight Kg Lbs  
F35/FA35, F40/FA40, F48/FA48, F60/FA60 Yes Yes 639.91 1411 No
Couplings
Coupling name Coupling Type Standard Dimension Max Dimension Min Dimension
mm in mm in mm in
N/A Female Square 153 6.00 153 6.00 0 0.00
Actuator Performance
Size Rated Torque Output RPM Rating  
  Nm lbsft RPM (50Hz) Starts / Hour  
IQS35 320 236 48.00 60  
Available for power supply Available Enclosures Weight
1-Phase AC 3-Phase AC DC Hazardous Watertight Kg Lbs
Yes No No Yes Yes 74.91 165
Handwheel Type Ratio Turns Rimpull
    (:1) (per stroke) N Lbsf
Standard SSHW 22.3 - 362 81
Sales/Technical Information: IQS - 1-Phase
Gearbox Performance
Size Rated Torque Ratio MA Weight
  Nm Lbsft (:1)   Kg Lbs
MTW11R 93550 69000 439 169.0 565.00 1246
Sales/Technical Information: MTW

Enter your specific requirements and click ‘Add to enquiry’

Fields marked with an * are required.

« Go Back